Parking Garage

Serialize function tia portal

  • Serialize function tia portal. Cookies are important for this site to function properly, to guarantee your safety, and to provide you with the best experience. Then, on the first screen, click on “Create a new project”, give it a name (“Box sorting machine” in this instance), and click on “Create”. Dec 31, 2021 · Joined: 1/17/2013. B. 0 Serializes a sequence of data/objects into a compressed JSON data stream. 2011. There are some tricks available, since you are working with the CPU1215. Highlights SIMATIC STEP 7 V16. All you need to know about ramp function in TIA Portal. On the other Sep 9, 2021 · Fig. function blocks) in a library (see Figure 1-1: Typification with libraries). STRING, size=254) public String abc; } In TIA, I created a data block variable of type string which 西门子TIA博途043课_Serialize:序列化是西门子TIA博途入门到精通(前半部)的第43集视频,该合集共计198集,视频收藏或关注UP主,及时了解更多相关视频内容。 Adding Elements to a Siemens HMI Screen in TIA Portal Step 1 - Creating a project in TIA Portal. be/Mpwa4AVvxVoBasic PLC programming tutorial for Beginners how to work wit · the migration of an S7-300/400 RFID project based on FB45 to S7-1500 (TIA Portal). The first thing you will notice is that both data blocks are exactly the same, that is because as we said the default setting when creating a data block is that it will be optimized, so we need to change the setting of DB2 to make it a standard block, to see if something will change. Rating: (720) In programming manual it's stated that non-optimized data are reordered to little endian when accessed. 10. Start by launching TIA Portal. I need to send email via gmail account with T_MAIL_C function. In this part, we will discuss the simple move, deserialize and serialize, move block, move block variant and uninterrupted move The configuration of the function blocks is performed in the TIA Portal as of V12 SP1. 6 75 100 150 200 250 The increased work memory allows the user to create projects that can do more Up to 2/3 additional through FW update for HW generation V4 (6ES721x-1xx40-0XB0) Can also be used with earlier versions of the TIA Portal (subscription); Variety of different TIA Portal options, e. May 25, 2020 · Note how SERIALIZE can tell you what the BYTE size of the structure is. It's a method of grouping variables of the same data type in a long list, and accessing each internal element via an index. Sep 7, 2018 · Basic PLC programming tutorial for Beginners how to work with move operations in TIA V13 and how to work in TIA Portal V13/V14. Sep 6, 2021 · My problem is, that Siemens Ident Profile functions operate only on byte array DBs. In my program I dont want to have to access each of these alarms using DB20. The correspondant chapter can be find by selecting a function of the library and pressing F1. I also found a way to serialize to the optimized instance data block and I avoided "unoptimized" memory areas completely. Inside the function, have a large enough byte array in Temp area. Siemens TIA Portal has one of, if not the best, Library management control systems. I would expect something similar to work for STL files for the pro version. Project library – Integrated in the project and managed using the project – Allows the reusability within the project 2. These functions will be shortly explained here, with a synthax description. stringify() as usual on the function or object containing the function, and call Function. Learn how to use function blocks, timers, and data blocks to create the basic functionality of a mixing process that would allow us to replicate the tank as needed in Siemens TIA Portal. Although we will be using TIA Portal version 16, other TIA Portal versions are equally appropriate. 0. Bewertung: (13) Hallo zusammen, ich habe eine CPU1516 mit TIA Portal V13 SP1 Upd6 projektiert, und verwende die Vergleichsfunktion LGF_CompareVariant aus der LGF (Library of General Functions) zum Vergleichen von zwei Strukturen, die unter anderem auch ein Array[1. The manual provides you with an overview of the system functions, organization blocks and loadable standard functions available with an S7 programmable controller and contains detailed Apr 28, 2021 · Note: You are free to use the programming language of choice which fits best to your needs. 1 Configure hardware in TIA Portal. All you need to do is call JSON. 2 Solution 2. Then you can clear each element of that array. TIA Portal Elementen (z. Aug 13, 2024 · The correct way to do this in recent versions of TIA would be: READ_LITTLE / READ_BIG. Oct 27, 2020 · dchartierDaniel Chartier Hello Daniel ChartierIs there any way like as Simatic manager V5. Es decir, se pude decir que un operando DTL tiene en su interior 12 operandos diferentes con diferentes tipos de datos, cada cual va a representar un valor de año, de Mes Apr 16, 2022 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Mar 27, 2022 · The use of Add Function isn't working, because TIA Portal is converting Int into DInt before execution of the "Add Function" Hello. In this tutorial, we will be using Tia Portal V16. Rating: (9) How can I convert an array of Char To a String? I know chr2str, but that function exist in TIA PORTAL only, isn't it? You have the option of creating types or master copies from TIA Portal elements (e. Today, I found myself setting up some simple point-to-point serial communication on a Siemens S7-1200. The help fileis decent enough. Regards! If this post actually helped, you may consider using the Rate button above. The project was converted to V16. El parámetro OUT es donde tenemos que insertar la variable donde se va a almacenar el resultado de la operación, es decir, el cociente. 0 Deserializes a compressed JSON data stream into a sequence of data/objects. A good place to start will be to take the tutorial The Complete Practical Guide to Siemens Tia Portal Programming; TIA Portal – TIA Portal V16 is being used in this tutorial; An installation of PLCSIM Differences between Function and Function Block Jul 21, 2021 · Tự học lập trình PLC, lập trình HMI với Tia portal Siemens, khóa học miễn phí dung lượng 3 ngày, giúp bạn biết lập trình plc và hmi siemens An installation of Tia Portal. A complete description can be find in the online-Help system of STEP7. You can actually mix and match all of the Timer types with any of the data types, and the project will compile and operate without issue. Apr 7, 2024 · From TIA Portal with an open project with an s7-1200/1500 PLC, open OB1 (or some other program block) in the working pane. Apparently Functions use Newtonsoft by default. the function "SERIALIZE" made the trick, since the output of the SERIALIZE function gives you the size of the passed object (if you start serializing from 0). Learn how to get up and running with Libraries in ~2 hours. FB286 is integrated in the libraries of the TIA Portal software. An understanding of using SCL instructions; Utilizing regions Qué es una función Move TIA Portal. Example: Tipos de datos DTL en TIA Portal. TIPs: E. 1 Overview Configuration Control with Diagnostic Entry ID: 29430270, V2. It effortlessly converted the serialized string back into the original data structure, allowing me to work with the data as needed. Take caution if you are updating already running application! Mar 26, 2014 · Hi, As from STEP7 V13, it is possible to copy values from an optimized DB (with user data type variables) to non optimized DB (as array of bytes) and vice versa with use of the blocks Serialize / Deserialize (S7-1500 CPU). X to initialize a DB in TIA Portal?----- TIA Portal Elementen (z. If you have any question ple Oct 17, 2023 · Hello everyone. If you have configured a connection in STEP7 (TIA Portal), the connection resource is occupied as soon as the hardware configuration has been loaded into the CPU. E. Using simple examples, we will show you the advantages offered by a high-level programming language. 2022. I hope this can help others too! Suggestion An installation of TIA Portal software on your computer. Asignar el tipo de datos. · the FB45 function block for the use of RF200/300/600, MOBY D/U with a SIMATIC S7-1500 in STEP 7 V13. As far as i know the String data are not allowed in symbol table as well as any other structured data (Struct, Array and so on), you can define those data in DBs, UDTs or blocks declaration. Before the utilization of FB286, make sure the configuration is completed in TIA Sep 21, 2016 · Ob der Ansatz mit AT oder der Ansatz mit Serialize / Deserialize besser ist und ob es sich eher lohnt, sich über die Performance Gedanken zu machen oder eher über die Einfachheit des Programms oder andere Gesichtspunkte, hängt von der Anzahl (pro Sekunde) der normalen Zugriffe auf die Struktur ab, von der Anzahl (pro Sekunde) der Serialize Aug 31, 2015 · Beigetreten: 26. Programmed Connection FB286 is a function block for multiple parameter access, which calls the acyclic communication blocks RDREC/SFB52 and WRREC/SFB53 internally. B) data structure (32 bools, 20 bytes, 16 bools, 10 bytes), and I have to copy into an Serialize y Deserialize en TIA Portal - PROGRAMACIÓN SIEMENS Hoy vamos a ver para qué sirven estas dos funciones que puede que en algún momento te puedes preguntar ¿para qué diantre sirven? Y es que para empezar, hay que entender qué hacen estas dos funciones. Für die Version 1. WRITE_LITTLE / WRITE_BIG. Json which has no effect on my response data. For the current application, I was writing a simple function block to broadcast data to a Red Lion serial slave display, but there are a variety of situations in which you may need to do to this, such as Aug 4, 2011 · Hallo Miteinander,ich habe eine CPU1518 mit TIA Portal V14 Update 2 projektiert, und setze die Funktionen Serialize und Deserialize ein. . 601] format. Look in the external source files section of the project view. Now I need a general function to copy data between blocks, where I build variant pointers from db_any variables. SIMATIC STEP 7 (TIA Portal) impresses with its innovative engineering for proven and new SIMATIC controllers. Jul 30, 2023 · However, a not-so-well-known secret of TIA Portal is that all of these timer instance data types are actually an alias for the data type IEC_Timer. Aug 16, 2018 · You could possibly even make a generic function that accepts any UDT data types as input with the following: Have a function with Var input. Last visit: 6/25/2024. AddJsonOptions() but that seems to be for System. Now that we have defined all the machine’s specifications, we can start writing our PLC program. 2] of Bool beinhalten. 4 shows the program in the "Copy" function with the call and parameterization of the two instructions "Serialize" and "Deserialize". After this you have to download the entire program to Function blocks and functions Table 2-1: Function blocks and functions of the Library Name Version Description LStream_JsonDeserializer V1. ALPHR Technology Europe. Next, the student will be introduced to Sequential Function Charts and will be taught the fundamentals of programming SFC in Siemens TIA Portal Step 7 using S7-GRAPH. Hardware Creating a new project in TIA Portal. Select this course if you want to program SIMATIC S7 using a high-level programming language. Mar 26, 2020 · Joined: 10/26/2017. NET 6 with in-process functions. Posts: 1. not string to ascii string is a collection of character stored as array of character so u can convert individual character to ascii. Funktionsbausteine) zu erstellen (siehe Abbildung 1-1: Typisierung mit Bibliotheken). Feature / Function Benefits Extended Motion Control functions: • Speed-, positioning axis • Gearing • Camming • Kinematics with up to 4 interpolating axis u Simple programming of sophisticated Motion Control functions: • in the well known SIMATIC environment • for a high machine flexibility • E. 0, 11/2017 7 G 7 e d 1. Suggestion; To thank ; Quote; Answer May 1, 2023 · In the previous video we learned together simple move, deserialize and serialize, move block, move block variant and uninterrupted move block. zip converted for importing into TIA Portal *) END_FUNCTION. Jun 16, 2023 · SIMATIC STEP 7 is the world’s best known and most widely used programming software in industrial automation. DBX0. An installation of TIA Portal software on your computer. The configuration and parameter settings for the drives is realized as follows 1. 2024. What Siemens does not tell us by de conversion that it keeps the old versions in the project. For SINAMICS S120, using Startdrive V*** (or using GSD and also STARTER 4. %B0 should always return LSB no matter if the data is optimized or not. Aug 4, 2011 · Beigetreten: 04. Certainly, downloading TIA Portal 16 Upd6 on 365evn automation is free. Once the TIA Portal program starts in Portal view, select Create New Project, enter a new name for the project and click Create new project. I am very satisfied now. Jan 2, 2019 · I am using the bean method for reading a string from a S7-1200: public class MyBean { @S7Variable(byteOffset=0, bitOffset=0, type=S7Type. In „Contents“ each function is explained in details. We will be using the “Function” for simplicity. They are important components in a holistic industrial security concept. Introduction. Decirte también que, por defecto, la posición inicial de un array es 0 (esto es modificable en TIA Portal, pero en muchos otros software o lenguajes de programación, no) ¿Cómo Crear un Array en TIA Portal? Para poder crear un array en TIA Portal, necesitas de un Bloque de Datos (DB). 08. code. Misc others with only a single IN or OUT parameter, like GATHER, SCATTER, RD_SYS_T, TIME_TCK, LEN. 1 Overview Schematic layout In this video I am going to discuss ramp function with an actual example. To access data areas wit May 21, 2015 · Joined: 3/3/2014. Aug 15, 2012 · Siemens S7-1200 Serial Communication. 6, 12/2018 2 G 8 d Legal information Use of application examples Aug 13, 2012 · In the S7-1200 Basic version of the portal, you can import legacy (pre-TIA Portal) Step 7 SCL files and have the portal generate blocks. Please see the attached picture. Content: – Move value (MOVE) – Deserialize – Serial… TIA Portal convert BOOL to WORD and WORD to BOOL@muhamedpasic83 Oct 28, 2019 · Why are there three different types of FB instances?Find out here!If this video helped you, please consider helping me by joining my "GoFundMe" and donating This article is about the use of move instruction with the help of TIA PORTAL. So my understanding is that slice access to . An understanding of SCL Elements. AddMvcCore(). B. 2] of Bool (nicht optimierter Zugriff) 2 Bytes Länge. Multiuser addressing working in teams, PLCSIM Adv. Jul 5, 2023 · Additionally, I found that the unserialize() function, which reverses the serialization process, worked seamlessly with serialize(). Type in Serialize and press enter Dec 28, 2020 · Posts: 1. cz/ Zajímavá funkce "pohledů" na proměnnou další deklarací tagu datového typu AT a polem. and Test Suite for testing and simulation scenarios • TIA²: TIA Use Cases for OT/IT Integration based on OPC UA and involving Security measures in Mar 12, 2016 · One thing I use PHP's serialize function is to store data in cache (like APC's user's cache), in a PHP application : you cannot store objects as-is : you have to serialize them. 1 von Serialize/Deserialize hat ein Array[1. In previous courses we saw using SCL networks within FBD code. Beiträge: 292. Posts: 103. 0 PLC-Simulation software SIMATIC Control Function Library V1. Posts: 136. 1 (CFL) Library for TIA Portal SIMATIC MTP Creator V2. El tipo de datos DTL en TIA Portal utiliza una estructura de 12 bytes de datos donde se va a guardar toda la información de fecha y hora. Posts: 4685. For the latter, experience with SIMATIC STEP 7 based on TIA Portal corresponding to TIA-SYSUP or TIA-PRO2 is mandatory. 3. Jun 6, 2020 · Using S7-1200 on TIA Portal 1200Reading alarms in a PLC program - I have a Word that I have representing alarms. 5 Existing standard functions STEP7 contains a Standard-Library with standard functions for the handling and comparaison of strings or for string conversions. Text. Jan 22, 2018 · Serialize function needs to be v2. Arrays are one Inside this FC you will convert the entire structure of data into a byte array using the serialize function, then you will loop over the entire array and zero it out before finally converting it back to your original data using the deserialize function. 11. Sep 13, 2011 · If you needed a way to serialise Arrow Functions in ES6 I have written a serialiser that makes everything work. Posts: 416. They operate like the Serialize/Deserialize, but they want to take only an elementary type as the source / destination (respectively). Guideline for library handling in TIA Portal Entry ID: 109747503, V1. Added 433 conversion functions in total. Your DB should be reset to no data i. plcskilltree. g. Last visit: 5/27/2024. Regards. The "Serialize" instruction converts a PLC data type into a sequential display type and stores the structured data in the buffer memory "tempStore". Last visit: 8/28/2024. Update 6 (the latest update) for the “Totally Integrated Automation v16” brings some improvements, and fixes the crash from user feedback. Stability when working with the TIA Portal has been improved, partly based on the feedback from returned crash reports. com/free-guide-optin Lea Jun 29, 2016 · If you want to clear your data structure (write zeros in each element), then one way could be to use the Serialize function and convert your struct into a single array. Output the length of the Serialize Pos. blaja. Add framework for builtin functions, and add several built in FCs and FBs: Add several built in functions that can be called from expressions: All CONVERT and T_CONV functions, like INT_TO_WORD etc. Serialize the Var input to the byte array. 1 Add-In for TIA Portal We must first launch the Siemens TIA Portal. Rating: (16) Hello, TIA Portal experts and learners. Rating: (23) Hi Ichdezv. From there I can use the serialize and de-serialize commands to copy data block data to other data blocks which is great for moving large groups of data but I don't think it works for groups of tags unless I am missing something. Suggestion; To thank ; Quote; Answer Jan 20, 2020 · Joined: 9/23/2005. Would anyone reading this be willing to show me an example of the use of the VARIANT data type supported by the S7-1200? Aug 31, 2022 · How do I configure the Newtonsoft serialization settings for an Azure Functions app on . Furthermore, this documentation shows possible fields of application and helps you Dec 13, 2022 · This time, I will introduce the functions of Serialize and Deserialize. x). Working with the TIA Portal. In the instruction pane, at the top is a search box. Pick & Place, assembly or In the context of Siemens TIA Portal, libraries are powerful tools that allow engineers to create, manage, and share code and other program elements across various projects. 5 50 75 100 125 150 V18 V4. 1. STEP 7 V16 includes new functions for all phases of the engineering workflow. To conclude the module, function blocks used for continuous PID control will be introduced. 0, 03/2017 5 G 7 d 2 Solution 2. Here's what this course covers: Learn how to use the Project A basic understanding of function, function block and data block. En primer lugar, podemos definir una función Move TIA Portal como una instrucción que va a permitir copiar valores y datos de una zona de memoria a otra zona de memoria. As the cache is used only by one application, it is not necessary to use a format known by many languages ; so, serialize is OK Oct 5, 2022 · Learn how to use Arrays with Siemens TIA Portal >>> Arrays are an important data type in PLC programming. And in communication, and data processing functions I have to use strings and char arrays for data manipulation. Dec 14, 2019 · Dear all,I have an S7-1214 CPU, and TIA Portal V15. Start by opening TIA Portal from the Start menu. Last visit: 7/22/2024. Posts: 234. 0 to support optimized data. Last visit: 9/3/2024. Una vez insertado, debemos de conocer varios pasos para configurar la función Calculate en TIA Portal correctamente: Parámetros de la función Calculate en TIA Portal. X to initialize a DB in TIA Portal?----- Jul 25, 2011 · Joined: 1/30/2006. Durch die Verwendung von Typen, werden diese im Projekt "instanziiert". These libraries come in two main categories: project libraries and global libraries. Siemens is pretty good at programming with structs and arrays. com/En este vídeo te muestro qué es la Función MOVE en TIA Portal, cómo funciona, para qué puedes utilizar esta instrucci Jan 3, 2018 · Pro články (for website) https://www. Formatting SCL code These functions will be shortly explained here, with a synthax description. LStream_JsonSerializer V1. For example, if I wanted to access Element 17 from the Array_1 in the above image, I would use Array_1[17]. TIA Portal V17 Upd4 Engineering tool WinCC Unified V17 HMI Engineering tool and RT S7-PLCSIM Advanced V4. Jul 13, 2021 · Currently I am using the MOVE function to individually move one tag at a time to the data block. com/serialize-y-deserialize-en-tia-portal/ Subscribe to this channel for more Videos and Tutorials 😊See also : https://youtu. 6. Global library Aug 7, 2023 · Yes, the root cause of this problem was that my project was originally created in Tia portal V14. May 15, 2023 · Visita mi WEB: https://www. Beiträge: 314. TIA Portal is a software and tools package developed by Siemens, which aims to integrate multiple development tools for automation devices from the unification and remodelling of preexisting software such as Simatic Step 7, Simatic WinCC, and Sinamics Starter. 2 Libraries and library elements in TIA Portal Figure 1-2: Libraries in TIA Portal 1 2 4 3 1. Primero debemos insertar el bloque dentro del segmento que vayamos a programar. Standard Functions Reference Manual The S7 CPUs have system functions and organization blocks integrated in the operating system that can be used when programming. To do this, double-click over the TIA Portal icon on the desktop or press the Windows button on the bottom left side of the screen, scroll down through apps until you find and expand the Siemens Automation folder, and then click on the TIA Portal icon to open it. In this article, I share the link to download the TIA Portal V16 update. An understanding of how to create an SCL block in the TIA Portal. May 4, 2022 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright In this video, the PLC Move Instruction will be investigated. Letzter Bes: 30. Rating: (0) Hi , I need help regarding the conversion of DINT value into two INT in S7-1200. mit dem MOVE_BLK_VARIANT, indiziert zu kopieren, so das Datentyp nicht gleich sein müssen und die Daten nicht als Array vorhanden sind, vom Beispiel der absoluten Adressierung Knowledge of SIMATIC S7 based on the TIA Portal corresponding to TIA-SCL1 or extensive experience with related high-level languages such as Pascal, C or Basic. With this in mind, Siemens’ products and solutions undergo continuous development. Based on the available solutions that I had seen in the topic section, the only way to do this is by SLICE through SCL. tecnoplc. Serialize (S7-1500) In Update 3, it is once again possible to link, to the parameter "DEST_ARRAY", an operand whose access path contains an ARRAY with a variable index. program complex code in an SCL Block and interlocking section of Outputs in an FBD Block. 0 etcI want to assign each of these to a logical bit in a pred Cómo configurar la función Calculate en TIA Portal. In the Startup, I tried Services. Rating: (0) Hi guys, i'm in search for most basic example for reading and writing json file in plc 1511. Nos vamos a centrar en Serialize, porque deserialize hace justo lo contrario. An installation of PLCSIM Advanced- V4. 1. This means that it is easier to diagnose and reference but means there is a limit to the total number that can be assigned. e. If you use these two instructions, you can transfer the variables of the structure to the array at once (Serialize) and transfer the array to the structure at once (Deserialize). MOVE instruction plays a huge role in analog programming from changing the speed of the motor to changing temperature intervals, etc. Attachment. Grab My FREE GUIDE on How to Drastically Improve the Structure of your TIA PLC Applications Right Here:https://www. all bools are false, all strings empty all int=0 etc. deserialise on the other side for the magic to work. What settings i need? Jan 13, 2020 · So the solution is a little bit less elegant: serialize from original array of integers to temporary array of bytes, and then deserialize from temporary array of bytes to final destination array of bools. Jan 15, 2023 · Hi everyone! I am working on a Siemens plc (1200/1500), and I have two instruction that i have to perform. Puede que con esta definición te haya quedado todo claro, pero vamos a especificar qué datos puedes copiar, qué valores puedes Legal information Programming Guideline for S7-1200/1500 Entry ID: 81318674, V1. Bewertung: (10) Hallo, gibt es irgend eine Möglichkeit bei einem DB mit "optimierten Bausteinzugriff" einen Datenbereich, z. The Totally Integrated Automation Portal (TIA Portal) provides the working environment for end-to-end engineering with SIMATIC STEP 7 and SIMATIC WinCC. So the update program brings all functions to the V16 versions. Dentro de las funciones matemáticas TIA Portal, la función Dividir en TIA Portal tiene dos parámetros de entrada llamados IN1 e IN2 que son las variables que queremos dividir. A) data structure (40 bools, 40 bytes), and I have to copy into an array of USINT [0. Serialize y Deserialize en TIA Portal Toda la información en: https://programacionsiemens. · the functionality implemented through this block. Oct 9, 2023 · Libraries are the best way to control reusable code and can shave hours and hours off of a project. Rating: (28) Hi, i guess u can convert only character to ascii . Introducir la TIA Portal Firmware Version 1211 1212 1212F 1214 1214F 1215 1215F 1217 V17 V4. May 22, 2015 · Joined: 10/21/2013. The TIA Portal version 16 will be utilized in this tutorial; however other TIA Portal versions are also acceptable. Was Dec 19, 2020 · Hoy vamos a ver para qué sirven estas dos funciones (Serialize y Deserialize) que puede que en algún momento te puedes preguntar ¿para qué diantre sirven? Y es que para empezar, hay que entender qué hacen estas dos funciones. Last visit: 5/3/2024. In this video, Aug 16, 2018 · You could possibly even make a generic function that accepts any UDT data types as input with the following: Have a function with Var input. you use an array of bytes as non optimized DB. Project libraries reside within individual projects, storing blocks that are used frequently or for versioning purposes. 2. Letzter Bes: 22. Hope this will work. An installation of Modbus Poll (a simulation software that serves as a Modbus client) An installation of Modbus Slave (a simulation software that serves as a Modbus server) Setting up a new project in Tia Portal Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. To have this block available in library, you need to: - Have CPU with latest firmware selected in project (Right click CPU > Change device) - Have your program updated to v14 (Right click CPU > Update program). For SINAMICS G120, using Startdrive V12SP1+ (or using GSD and STARTER 4. hypgau ikrfs pdeby xmntbuo oix kpdqxte osqp ezoabmas bamjfm tspe